Aurora500

Solid Phase Extraction

Solid Phase Extraction

VERSA Automated Solid Phase Extraction (SPE) workstations fully automate SPE workflow from cartridge conditioning to sample derivatization on a single deck with innovative modules.

VERSA Automated Solid Phase Extraction (SPE) workstations fully automate SPE workflow from cartridge conditioning to sample derivatization on a single deck with innovative modules.

Automated solid phase extraction to concentrate and purify samples for analysis

The same platform can also perform liquid-liquid extraction (LLE), with options to have both Positive Pressure and Vacuum Manifold systems attached for various protocol functions. With the combination of the ReagentDrop™, Heater-Shaker, Gripper, and Nitrogen Dryer, these modules act to produce contamination-free sample pre-processing, and trace analyte enrichment, before analyzed by a chromatography-based platform (HPLC / GC).

VERSA SPE workstations are highly scalable for different throughputs and budget, from the compact VERSA 10 to the highly customizable VERSA 1100, for applications in forensics, environmental samples, pharmaceutical compound analysis (ADME), clinical samples, and food safety.

The same platform can also perform liquid-liquid extraction (LLE), with options to have both Positive Pressure and Vacuum Manifold systems attached for various protocol functions. With the combination of the ReagentDrop™, Heater-Shaker, Gripper, and Nitrogen Dryer, these modules act to produce contamination-free sample pre-processing, and trace analyte enrichment, before analyzed by a chromatography-based platform (HPLC / GC).

VERSA SPE workstations are highly scalable for different throughputs and budget, from the compact VERSA 10 to the highly customizable VERSA 1100, for applications in forensics, environmental samples, pharmaceutical compound analysis (ADME), clinical samples, and food safety.

SPE-flowchart

Applications – VERSA Automated Solid Phase Extraction Systems

  • Food Safety
  • Vitamin D from Blood/Serum Samples
  • Drugs of Abuse in Forensic Analysis
  • Food Safety
  • Vitamin D from Blood/Serum Samples
  • Drugs of Abuse in Forensic Analysis
  • Compounds for Drug Discovery
  • Iso-Flavonoides from Urine Samples
  • Aflatoxins from Seafood Products
  • Compounds for Drug Discovery
  • Iso-Flavonoides from Urine Samples
  • Aflatoxins from Seafood Products
  • Growth Promoters in Blood
  • Semi-Volatile or Non-Volatile Analytes
  • Protein Precipitation
  • Growth Promoters in Blood
  • Semi-Volatile or Non-Volatile Analytes
  • Protein Precipitation

Modules Tailored to Automate Your Entire Solid Phase Extraction Workflow

Compatability150

Compatibility with Different Commercial Cartridges

1, 3, 6 mL Cartridges & 96 SPE Cartridge Plates

vacuummanifold150

Vacuum Manifold (Negative Pressure)

ensures samples and reagents flow through cartridges efficiently

PositivePressure150

Positive Pressure Module

ensures samples and reagents flow through cartridges efficiently

Gripper150

Gripper

moves cartridge block and nitrogen dryer for on-deck washing, elution, nitrogen drying and derivatization

NitrogenDryer150

Nitrogen Dryer

enables on-deck nitrogen drying for derivatization

ReagentDrop150

ReagentDrop

draws reagents from their reservoirs and eliminates tip usage

ShakerHeater150

Shaker-Heater

allows efficient sample pre-processing and derivatization

ReagentBlockCooler150

Reagent Block Cooler

cools reagents for derivatization

SPECartridgeHolder150

SPE Cartridge Holder

works with Gripper to automate Wash, Elution and Fraction Collection steps

Specifications

Deck Capacity: 15

Pipetting Head (Single Channel Function, Disposable Tip): 4 or 8 channel

ReagentDrop: up to 8

Supported Cartridges: 1, 3 or 6 mL cartridges or 96 SPE cartridge plate

Gripper: Gripper

Pressure Module(s): 4 channel positive pressure module and/or vacuum manifold (negative pressure)

Nitrogen Dryer: 24 or 96 channels

Shaker-Heater (2400rpm, RT to 90°C): Optional

Reagent Block Cooler: Optional

Liquid Level Sensing: Optional for Liquid Liquid Extraction

HEPA/UV/LED Enclosure: Included

Width x Depth x Height (cm): 99 x 75 x 90

Weight (kg): 162

Automated solid phase extraction to concentrate and purify samples for analysis
  • Capable of performing Automated Liquid Extraction on the same workstation
  • Compatibility with organic and aqueous reagents
  • Exhaust provision for volatile reagents
  • HEPA/UV/LED Enclosure – keeps samples contamination-free
  • Unparalleled Customer Service – our engineering team is readily available to troubleshoot your protocols, full application support to requirements
  • Capable of performing Automated Liquid Extraction on the same workstation
  • Compatibility with organic and aqueous reagents
  • Exhaust provision for volatile reagents
  • HEPA/UV/LED Enclosure – keeps samples contamination-free
  • Unparalleled Customer Service – our engineering team is readily available to troubleshoot your protocols, full application support to requirements

Consider automating your SPE today!

Consider automating your SPE today!

Need more information / Questions?

Need more information / Questions?

Please contact us by phone or email:

Freephone 0800 724 633

info@scienze.nz

Or use the contact form below:

Please enter your name.
Please enter a message.

Excellence in Scientific Solutions

A to Z Product Listing

A to Z Product Listing

Copyright © 2024, Scienze. All rights reserved.