logo-tissuegnostics

TissueGnostics is a solution provider for Precision Medicine and provides fully integrated cutting-edge tissue cytometers including a multitude of configurations from multispectral & high-throughput scanning to contextual tissue cytometry. The goal of TissueGnostics is to bring the same type of phenotypical analysis of single cells from Flow Cytometry into tissue context. For more infomation about TissueGnostics and Precision Medicine, please follow the link to the dossier "FIGHT CANCER! The age of precision medicine has dawned".

HIGH-THROUGHPUT SYSTEMS

TissueFAXS SL
SLIDE LOADER

HIGH-THROUGHPUT SYSTEMS

TissueFAXS SL
SLIDE LOADER

TissueFAXS SL
SLIDE LOADER

All TissueFAXS upright systems configurations (Fluo, Histo, PLUS) are also available as TissueFAXS SL (Slide Loader) high-throughput systems.

In this configuration, they are additionally equipped with an automatic slide loader and a specially adapted version of the TissueFAXS scanning and image management software.

This software version also includes TGs new SV (Slide Validator) technology.

TissueFAXS SL systems are also available in scan only configurations.

 

TissueFAXS SL systems can be upgraded to the same configurations as the non-loader systems (Histo and Fluo to PLUS, epifluorescence to confocal or high-speed).

TissueFAXS SL
SLIDE LOADER

All TissueFAXS upright systems configurations (Fluo, Histo, PLUS) are also available as TissueFAXS SL (Slide Loader) high-throughput systems.

In this configuration, they are additionally equipped with an automatic slide loader and a specially adapted version of the TissueFAXS scanning and image management software.

This software version also includes TGs new SV (Slide Validator) technology.

TissueFAXS SL systems are also available in scan only configurations.

 

TissueFAXS SL systems can be upgraded to the same configurations as the non-loader systems (Histo and Fluo to PLUS, epifluorescence to confocal or high-speed).

TissueFAXS SL
UNIQUE FEATURES

  • Fully automated high-throughput scanning - up to 120 slides
  • Option for oversized slides
  • Slide ID Scanner
  • Multi-channel fluorescence & brightfield
  • Extended Focus Imaging & Z-Stacking
  • Quantitative image analysis option
  • Image and metadata storage, management and archiving
TF-SL-PLUS-3.4-right-intro

TissueFAXS SL
TECHNOLOGY

TissueFAXS SL integrates TissueGnostics Slide Validator technology to ensure a high level of digital slide sharpness. Each scanned FOV is evaluated for sharpness on-the-fly during the scan process.

If the validation algorithm deems the FOV to be not sharp enough it will be rescanned on-the-fly.

CONFIGURATION

TissueFAXS SL systems are loaded with up to three 40 slide magazines with each magazine containing 20 two slide metal clips for a total of 120 standard slides.

Alternatively, 60 double sized (76 × 52 × 1 mm) slides can also be loaded and scanned, making TissueFAXS SL system one of the few in the market capable of doing this.

The clips are magnetically gripped and moved out to the stage for scanning. In this way, any contact of the slides with moving parts is prevented, safeguarding them against breakage.

TissueFAXS SL systems provide automatic scanning of brightfield and/or fluorescence slides. TMA scanning is supported in all configurations. Combined with TissueGnostics integrated high-speed cameras it provides high-throughput for slides with a speed and versatility in the top range.

TissueFAXS SL is capable of oil immersion scanning.

TissueFAXS-SL-Configuration

TissueFAXS SL
Workflow

TissueFAXS SL comes with a new version of the TissueFAXS software designed for the perfect handling of the high amount of samples, data validation and storage. There are two main workflows, a simple workflow for one type of slides and an advanced workflow for mixed samples types:

SL-Flowchart

PROPERTIES

Design: Modular (Microscope, Automatic Slide Loader, Cameras, Light-source, PC with 2 Monitors)

Microscopy mode: Fluorescence, Brightfield

Compatible Slide Formats: All standard and over-sized slides

Slide Capacity: 120

Objectives: Up to 7 Objectives (2.5-100x)

FL-Channels: 9

Camera: CCD Camera (14-bit, 1.4 Megapixel, Monochrome). CMOS Camera (8/10-bit, 4.2 Megapixel, Color)

Light Source: VIS-LED, Solid-state Light Engine

Tissue Microarray (TMA): YES

Image Analysis Software: QUEST line (Algorithms for tissue detection, area measurement, scattergrams for cells and many more)

Supported Image Formats: TissueFAXS, OME-TIFF, TIFF, JPEG, BMP, PNG

Viewer: Integrated, stand-alone freeware

TGLogowhite

REFERENCES

TissueGnostics has over 1,500 scientific reference publications

Learn more ›

REFERENCES

TissueGnostics has over 1,500 scientific reference publications

Learn more ›

Need more information / Questions?

Need more information / Questions?

Please contact us by phone or email:

Freephone 0800 724 633

info@scienze.nz

Or use the contact form below:

Please enter your name.
Please enter a message.

For Greater Productivity & Insights

For Greater Productivity & Insights

Copyright © 2020, Scienze. All rights reserved.